IS 2062 — Structural Steel Grades

The steel every structure on this site is made from. What the grade number means, what the letter after it changes, and why the letter is the part buyers get wrong.

IS 2062 is the specification for hot rolled medium and high tensile structural steel. The grade designation is direct: E250 means a minimum yield stress of 250 MPa, E350 means 350 MPa, and so on.

The part that causes trouble is the letter after the number. A, BR, B0 and C are not strength grades — the strength is identical. They differ only in the Charpy V-notch impact test, and therefore in how the steel behaves when it is cold, shocked or dynamically loaded.

Grades and mechanical properties

GradeMin. yield stressMin. tensile strengthMin. elongation
E250250 MPa410 MPa23%
E350350 MPa490 MPa22%
E410410 MPa540 MPa20%

Yield stress is quoted for the lower thickness range. Yield falls as section thickness increases — always check the allowable against the actual thickness rather than the headline grade figure. Higher grades (E450 and above) exist in the standard for specialised work.

The sub-designation is the bit that matters

Same strength, different toughness. This is where a specification is won or lost.

Sub-gradeCharpy V-notch impact requirementWhere it belongs
ANo impact test requiredNon-critical fabrication and general-purpose work
BR27 J minimum at room temperatureMost general construction in moderate Indian climates
B027 J minimum at 0 °CCold climates and dynamically loaded structures
C27 J minimum at −20 °C or lowerCritical low-temperature and high-consequence work

A drawing that says only “IS 2062 E250” has not specified toughness. For a transmission tower in a Himalayan corridor or a structure carrying dynamic load, that omission is the difference between the right steel and the cheap one.

What Indo East uses it for

  • Telecom towers and monopoles, substation and transmission structures, railway OHE structures, solar module mounting structures and heavy structural fabrication are all built from IS 2062 material.
  • Chemistry is verified in-house on a Bruker Q2 ION optical emission spectrometer imported from Germany and commissioned in June 2026, reading steel, zinc, aluminium and copper. Mechanical properties are checked on a universal testing machine and an analogue Rockwell hardness tester.
  • Mill test certificates travel with every consignment. Where a specification demands a grade and sub-grade we have not been asked for before, we confirm availability before quoting rather than after.

Questions engineers ask

Answered from our own line, not from the standard's cover page.

What does E250 mean in IS 2062?

A minimum yield stress of 250 MPa. The number in the grade designation is the yield figure directly. E250 also carries a minimum tensile strength of 410 MPa and 23% minimum elongation.

What is the difference between IS 2062 E250 A and E250 BR?

Strength is identical. They differ only in the Charpy V-notch impact test: Grade A requires none, BR requires 27 J at room temperature. For dynamically loaded or cold-service structures the sub-grade is the specification that matters, not the yield number.

Does yield strength change with plate thickness?

Yes — it falls as thickness increases. The headline grade figure applies to the lower thickness range. Always work the allowable stress from the actual section thickness in the drawing.

Do you verify the steel chemistry yourselves?

Yes. We run a Bruker Q2 ION optical emission spectrometer on site, imported from Germany and commissioned in June 2026, reading steel, zinc, aluminium and copper. We also run a universal testing machine and a Rockwell hardness tester, and an in-house tool room for jigs and fixtures.

Which grade do you use for transmission line towers?

It is set by the design, not by us — IS 802 governs the tower and the designer specifies the grade and sub-grade. We fabricate to the drawing and certify what we used, with mill test certificates supplied against every consignment.

Related standards and pages

Send us the specification

Tell us the standard, the coating requirement and the component, and we will confirm in writing what we can hold and how we will certify it. Galvanizing is on our own floor, so the answer comes from us and not from a sub-contractor.

Request a quotation Galvanizing job work