Substation gantries, equipment supports, transmission line towers and distribution poles — built to utility specifications and third-party inspected.
Indo East supplies substation structures, transmission line towers and distribution steelwork from 33 kV to 765 kV — bus posts, gantries, equipment supports, deadend structures, lightning masts, and suspension, tension, deadend and transposition towers. Steel is IS 2062, design references are IS 802 and IS 875 Part 3, and galvanizing is IS 2629 and IS 4759 at 85+ microns on our own kettle.
We are an approved vendor to WBSEDCL, WBSETCL, OPTCL, BSPTCL, NBPDCL and SBPDCL among other state electricity boards, and to L&T, ABB, Siemens, Alstom T&D and Polycab. There are dedicated pages for substation structures, transmission line towers, monopoles and earthing materials.
Our power infrastructure range covers the full spectrum from 33kV to 765kV — substation structures, transmission line towers, and distribution structures. We are an approved vendor for WBSEDCL, WBSETCL, OPTCL, BSPTCL, NBPDCL, SBPDCL, and numerous other State Electricity Boards and engineering companies including L&T, ABB, Siemens, Alstom T&D, and Polycab.
All power structures are engineered for longevity in harsh outdoor environments. Our hot-dip galvanizing provides decades of corrosion protection, significantly reducing maintenance costs over the structure's lifetime.
| Parameter | Specification |
|---|---|
| Voltage Range | 33kV, 66kV, 110kV, 220kV, 400kV, 765kV |
| Structure Types | Bus Post, Gantry, Deadend, Lightning Mast |
| Tower Types | Suspension, Tension, Deadend, Transposition |
| Material | IS 2062 Gr. A, B, C; IS 8500; IS 1239 pipes |
| Galvanizing | IS 2629 / IS 4759 — 85+ microns |
| Insulators & Hardware | Polymer (composite) insulators, pole line hardware and fittings |
| Solar Module Mounting Structures | Module Mounting Structures for utility solar |
| Standards | CEA, IS, IEC and customer specifications |
Bus posts, gantries, and equipment supports for 33kV–765kV switchyards.
All tower types for EHV lines — suspension, tension, deadend, and angle towers.
Module Mounting Structures for utility-scale and rooftop solar projects.
11kV and 33kV structures for state distribution utilities.
Composite polymer insulators and pole line hardware supplied alongside our distribution and transmission structures. Ratings quoted against the customer's specification.
Substation and transmission structures, line hardware and earthing materials — all of it fabricated and hot-dip galvanized on one floor at Jangalpur, Howrah, to IS 2062 steel and a 75–85 micron coating read on a calibrated gauge, batch by batch. One company is accountable for the fabrication and for the coating.
| Item | What it is | Standards | Detail |
|---|---|---|---|
| Substation structures | Gantries, equipment supports, take-off structures and lightning masts for 33 kV to 765 kV substations | IS 2062; IS 875 Part 3; IS 802 | Substation structures → |
| Transmission line towers | Lattice towers and tower parts fabricated to the utility drawing | IS 802; IS 875 Part 3 | Transmission line towers → |
| Monopoles | Tubular and polygonal poles for distribution and transmission, where right of way is tight | IS 2062; IS 875 Part 3 | Monopoles → |
| Pole line hardware | Cross arms, stay sets and rods, plates, brackets, yoke plates, clamps and dead-end fittings for 11 kV and 33 kV lines | IS 2486 Parts 1–4; IS 2141 stay wire | Pole line hardware → |
| Earthing materials | Electrodes, strip, clamps and accessories for substation and line earthing | IS 3043 | Earthing materials → |
| Foundation and anchor bolts | The structure-to-foundation interface, in the grade the design calls for | IS 1367, classes 4.6, 5.6 and 8.8 | On this page |
| Hot dip galvanizing | All of the above, dipped in our own 7 metre kettle rather than sub-contracted | IS 2629; IS 4759; ASTM A123 or EN ISO 1461 where specified | Galvanizing → |
Send the drawing, the bill of materials or the tender specification and we will price it line by line. Third-party inspection by SGS, Bureau Veritas, TÜV, DNV or Intertek is supported at stages agreed before production.
33 kV, 66 kV, 110 kV, 220 kV, 400 kV and 765 kV - covering substation structures, transmission line towers and 11 kV / 33 kV distribution structures.
Bus posts, gantries, deadend structures, lightning masts and equipment support frames for 33 kV to 765 kV switchyards, plus feeder pillars.
Suspension, tension, deadend and transposition towers for EHV lines, fabricated to the utility's or EPC contractor's approved drawings.
IS 2062 Grades A, B and C, IS 8500 high-strength steel, and IS 1239 pipes. Hot-dip galvanizing is to IS 2629 / IS 4759 with a coating of 85+ microns.
Approved vendor for WBSEDCL, WBSETCL, OPTCL, BSPTCL, NBPDCL and SBPDCL among other State Electricity Boards, and for engineering companies including L&T, ABB, Siemens, Alstom T&D and Polycab.
CEA, IS, IEC and BS standards, or the customer's own specification where one is issued.
Yes. Fabrication and hot-dip galvanizing happen on the same Howrah site, in a 7-metre kettle (7 m x 1.2 m x 1.6 m). Nothing is sent out for coating.
Yes. Composite polymer insulators, pole line hardware and fittings are part of the power range and are supplied alongside our substation, transmission and distribution structures, so a utility or EPC buyer can source the structure and its hardware from one vendor. Voltage class, creepage and mechanical rating are quoted against the customer's specification.
Yes. Power structures are routinely supplied against third-party inspection to utility specifications.