+91 98361 05950 info@indoeast.com NH-6, Jangalpur, Howrah – 711411, West Bengal, India

Double Dipping and Kettle Size

How long a piece can be galvanized in one immersion, what happens to the steel that is longer than the kettle, and how to design a member so the question never arises.

The longest piece a galvanizer can coat in one immersion is set by the internal dimensions of the kettle — and a piece can be dipped diagonally, so the usable length is the kettle’s diagonal rather than its length. Anything longer than that has to be double dipped: one end is immersed, withdrawn, the piece is turned end for end, and the other end is immersed to complete the coating.

Double dipping is a normal, accepted practice. It is also the single thing most likely to change how a finished member looks and behaves, and it is the reason kettle size decides more galvanizing enquiries than price does.

Indo East’s kettle is 7.0 m long × 1.2 m wide × 1.6 m deep, working at 450–460 °C. Members up to about 7 metres go in on one dip. Longer members are double dipped, and we say so before quoting rather than after the steel is in the zinc.

Length is negotiable. Width and depth are not.

The most common misreading of a galvanizer’s capacity.

Kettle dimensionWhat it limitsCan double dipping get around it?
LengthThe longest member that fits in one immersionYes. Progressive dipping roughly doubles the treatable length, provided at least half the piece fits in the bath
WidthThe widest assembly — a portal frame, a wide bracket, a bolted sub-assemblyNo. A piece wider than the kettle cannot be dipped at all, at any number of dips
DepthHow much of the piece is submerged in each pass, and therefore the practical dipping angleNo. Depth is a hard ceiling and it is what makes the diagonal work

This is why “how long is your kettle?” is only the first of three questions. A 12 metre kettle that is 1 metre wide will refuse an assembly a 7 metre kettle 1.2 metres wide accepts.

What double dipping actually costs you

Four consequences. None of them is a defect, and all four are worth knowing before you specify.

  • A visible overlap line. Where the two immersions meet there is a darker band of heavier coating. It is cosmetic, and it weathers out as the surface dulls to uniform grey. On architecturally exposed steel it matters; on a tower leg it does not.
  • Extra zinc in the overlap. The band gets two exposures to molten zinc. Coating standards set a minimum thickness and no maximum, so the build-up is not a non-conformance — but where it falls on a faying surface or a bolted connection it can need buffing back to let the joint close.
  • A real distortion risk. The piece is heated and cooled unevenly: one half is at 450 °C while the other is in air. The resulting thermal gradient is what warps steel, and the first dip carries the greatest risk because the gradient is steepest. Long, slender, asymmetric and thin-walled sections are the ones that move.
  • More handling, more cost, more cycle time. Two immersions, a turn between them, and more crane work. It is priced accordingly, and a galvanizer who quotes a double dip at the single-dip rate has probably not read your drawing.

How to keep a member out of a second dip

In order of how much they help. The first one solves the problem outright.

ApproachWhat it means in practiceWorth it when
Split the memberDesign the long member as two or more sections within kettle length, joined by a bolted splice or a site weld after galvanizingAlmost always, on anything you are still free to redesign. A splice plate costs less than a distorted member
Design the vent and drain holes for speedGenerous, corner-located openings let the piece go in and come out faster, which shortens the time the two halves spend at different temperaturesEvery time. See vent and drain hole design
Brace it temporarilyTemporary stiffeners or bracing across the section, removed after galvanizingSlender or asymmetric sections that would otherwise warp
Agree the lifting orientation firstWhich end goes in, at what angle, on what jig — settled between you and the galvanizer, not improvised at the kettleAny double dip. It is the cheapest risk control available
Change the coatingThermal spray zinc, or hot dip galvanizing the sub-assemblies and metallising the field jointsGenuinely oversized fabrications that cannot be split

What the standards say — and what they do not

Worth knowing before an inspector is standing at your consignment.

  • None of IS 2629, IS 4759 or ASTM A123 prohibits double dipping. The coating requirement applies to the finished member as a whole, including the overlap. Dip count is a process decision, not a compliance one.
  • Coating thickness figures are minimums. ASTM A123 sets no maximum, so heavier coating in the overlap band does not fail the specification on thickness. What can fail is adherence — very heavy coating is more brittle — and appearance, where the specification calls for a continuous, smooth, uniform finish free of gross deposits.
  • What the standards will not do is settle it commercially. If the overlap band is unacceptable to you on visual grounds, say so in the enquiry. An inspector cannot reject on a preference that was never written down.

What to ask a galvanizer, and in what order

Five questions. The first three eliminate most vendors before price is discussed.

  • 1. What are the internal length, width and depth of your kettle? All three, not just the length. A single number is an incomplete answer.
  • 2. Will my longest member go in on one dip? Give the length, the section and the overall width of any assembly.
  • 3. If it will not, will you tell me before you quote or after you dip? The answer to this predicts most of what follows.
  • 4. Who carries the risk if a double-dipped member distorts? Settle it in writing. It is the most common dispute in job-work galvanizing.
  • 5. What coating figure will you certify, and read on what instrument? In microns or g/m², batch by batch. See the coating calculator to convert whichever your specification uses.

Where Indo East sits, stated plainly

7.0 m × 1.2 m × 1.6 m, 450–460 °C, in our own kettle at Jangalpur. Members up to about 7 metres are galvanized in a single immersion to IS 2629, IS 4759 and ASTM A123 at 75–85 microns, read on a calibrated dry film thickness gauge, batch by batch.

Longer members are double dipped. We raise it when we read the drawing, not when the steel is in the zinc, and we will tell you what the overlap will look like and where it will fall on your member before you place the order.

And the part most suppliers leave out: if your member has to be single dipped and it is longer than our kettle, we are the wrong works for that piece and we will say so. There are kettles in this country at 12 metres and more. Knowing which question you are actually asking is worth more to you than winning the enquiry is to us.

Because the galvanizing is on our own floor rather than sub-contracted, the dipping decision and the coating record come from the same works — see in-house versus sub-contracted galvanizing.

Questions engineers ask

Answered from our own kettle, not from a brochure.

What is double dipping in hot dip galvanizing?

Double dipping, also called progressive dipping, is galvanizing a piece that is longer than the kettle by immersing it in two passes. One end goes in, the piece is withdrawn and turned end for end, and the other end is immersed to complete the coating. It roughly doubles the length a kettle can handle, provided at least half the piece fits in the bath at a time.

What is the longest piece Indo East can galvanize in one dip?

About 7 metres. Our kettle is 7.0 metres long by 1.2 metres wide by 1.6 metres deep and works at 450 to 460 degrees Celsius. A piece can be dipped at an angle, so the usable length is the kettle's diagonal rather than its flat length, but 7 metres is the figure to design to. Longer members are double dipped and we raise that before quoting.

Does double dipping weaken the coating or the steel?

No, but it changes two things. The overlap band where the two immersions meet carries heavier coating, and very heavy coating is more brittle and can flake under impact. And the piece is heated and cooled unevenly, which introduces thermal stress and can distort slender or asymmetric sections. The steel itself is not weakened; the risk is dimensional and cosmetic.

Will the overlap line show?

Yes, at first. Where the two dips meet there is a darker band of heavier zinc. It is cosmetic and it fades as the whole surface weathers to a uniform matt grey. Where it matters is architecturally exposed steel, and where it falls on a faying surface or a bolted connection it may need buffing back so the joint closes properly.

Can a piece wider than the kettle be double dipped?

No. Double dipping extends length only. Width and depth are hard limits set by the kettle, and a piece wider than the bath cannot be galvanized in that kettle at any number of dips. This is why the width of an assembly, not just the length of a member, belongs in the enquiry.

Do IS 2629, IS 4759 or ASTM A123 allow double dipping?

None of them prohibits it. The coating requirement applies to the finished member as a whole, including the overlap, and the number of immersions is a process decision rather than a compliance one. Coating thickness figures in these standards are minimums with no maximum, so the heavier coating in the overlap band does not fail on thickness. Appearance and adherence requirements still apply.

How do I avoid double dipping altogether?

Design the long member as two or more sections within the kettle length and join them with a bolted splice or a site weld after galvanizing. A splice plate is cheaper than a distorted member and it removes the overlap band, the thermal gradient and the extra handling in one decision. Where the member cannot be split, generous corner-located vent and drain holes and temporary bracing reduce the distortion risk.

Who carries the risk if a double-dipped member distorts?

Whoever agreed to it in writing, which is why it should be settled before the order. Distortion in double dipping is a known and predictable risk on long, slender, thin-walled and asymmetric sections, and it is the most common dispute in job-work galvanizing. We raise it at drawing stage and agree the lifting orientation and jigging before the piece reaches the kettle.

My member is 10 metres and must be single dipped. Can you do it?

No, and we will tell you so rather than take the order. Our kettle is 7 metres and a 10 metre member would have to be double dipped here. There are kettles in India at 12 metres and beyond, and if a single immersion is a hard requirement for your piece, that is where it should go. If the member can be split, or if a double dip is acceptable once you have seen where the overlap falls, we are glad to quote.

Does a bigger kettle always mean a better galvanizer?

No. Kettle length decides what will fit; it says nothing about pre-treatment, coating control, testing or documentation. A larger bath is the right filter when your members are long, and the wrong one when they are not. For pieces inside our kettle the questions that actually separate galvanizers are whether the galvanizing is in-house or sub-contracted, what coating figure is certified, and on what instrument it is read.

Related standards and pages

Send the drawing with your longest member marked

We will tell you whether it goes in on one dip, what a second dip would do to it, and whether splitting it is the better answer — before there is a quotation on the table. A formal offer typically goes back within 48 business hours.

Send an enquiry WhatsApp